抖圈为du而生

How to Choose the Right Differential Probe - Input Capacitance

2025-11-03 10:26

意识探头的输入电容.jpg

Input Capacitance

When selecting differential probes, the input capacitance value is typically listed as a parameter. The following factors should be considered:

Characteristics of the measured signal

Such as signal bandwidth/rise time. Typically, measuring high-frequency signals requires extremely low input capacitance. Since the input capacitance forms a low-pass filter with the impedance of the signal under test, higher capacitance results in a lower cutoff frequency, allowing fewer high-frequency signals to pass through. This consequently reduces the bandwidth of the test system.

Impedance of the measured signal

Similarly, even a very small input capacitance (such as 1pF) can form a low-pass filter with a cutoff frequency as low as approximately 160MHz at a high-impedance node (such as 1kΩ), severely limiting the usable bandwidth.

Resonance effect

The inductance formed between the probe input capacitance and the probe ground wire, combined with any inductance present in the circuit under test, creates a resonant circuit. A low input capacitance helps shift the resonance point above the measurement bandwidth, preventing resonance peaks within the frequency range of interest that could cause waveform distortion.

From the three points above, low output capacitance is critical for measurement instruments. Below is a comparison of recommended input capacitance ranges and probe types for different testing environments:

Characteristics of the measured signal

Recommended capacity range

Applicable Signal Frequency Range

High-speed digital signals

<1 pF

>1 GHz

Medium-speed signal

1- 5 pF

100 MHz-1 GHz

Low-frequency/high-impedance circuit

5-10 pF

<100 MHz

Probe Type

Capacitance range

Advantages

Active differential probe

0.1-1 pF

Minimal load, high bandwidth

Passive probe

4-10 pF

Low cost, durable

High-impedance single-ended probe

10-15 pF

Highly versatile

Therefore, users can select the appropriate probe based on the characteristics of the actual signal being measured and the application scenario before testing.